Installation
Electrical connections
23
Mounting
22
30
31
This diagram is valid
also for the open col-
lector modules with a
lower number of out-
puts. The value of the
load resistances (Rc)
must be chosen so that
the short-circuit current
is lower than 100mA;
the VDC voltage must
be lower than or equal
to 30 VDC.
Relay outputs
Open collector outputs
AO1058
single relay output
AO1035
dual relay output
AO1059 single open collector
output
AO1036 dual open collector
output
Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected]