Outputs / Other settings
Useful Info
49
Serial Outputs
54
56
55
RS 485
Select SERIAL OUTPUT
from the main menu,
then select
RS485 by means of the and
keys and confirm with .
Select the parameter to be set
from the available sub-menus
with the and keys and
confirm it with . The config-
urable parameters are:
ADDRESS of the instrument:
from 1 to 255.
BAUD RATE: 1200, 2400,
4800 and 9600 bit/s.
PARITY: no parity, even parity
and odd parity.
To exit from any of the menus or
reset a choice, press .
F
S
S
F
F
F
F
S
S
S
S
S
Digital Filter
Select FILTER by means of the and keys
and confirm it with . Select the function to be set
from one of the submenus with the and keys and
confirm it with . There are three possible choices:
DISPLAY, to select the display of the 4-digit (max 9999) or
3 1/2-digit (max 1999) instantaneous variables.
RANGE, to set the operating range of the digital filter. The
value is expressed as % of the full scale.